VTT develops device for the simultaneous measurement of several gases reducing indoor air quality

VTT Technical Research Centre of Finland Ltd has developed a real-time and reliable device that can be used to measure ammonia and formaldehyde concentrations particularly in indoor air simultaneously, unlike with the meters currently in use. It is also suited to the measurement of emissions reducing outdoor air quality in city centres and traffic. 

“The device is capable of measuring the concentrations of several gases reliably and continuously with a sensitivity of less than 10 ppb, and it reports the results rapidly in just a couple of minutes or, if necessary, in seconds. The prototype can be flexibly modified for different purposes”, says Senior Scientist Timo Rajamäki from VTT.

One ppb equals one billionth of the gas molecules in the air, so we are talking about extremely minute concentrations. In Finland the limit value for indoor air gas content that does not cause observable health hazards are around 20-30 ppb for ammonia (30-40 micrograms per cubic metre), and around 40-125 ppb for formaldehyde (30-100 micrograms per cubic metre), depending on the indoor climate class.

Emissions from interior design and construction materials are a common cause of indoor air problems. The most typical sources of formaldehyde and ammonia in indoor air are ceiling and wall levelling compounds, adhesives and plastic mats, and particularly the adhesives and solvents used in them.

The measurement method of VTT’s sensitive and real-time device is based on the absorption of light from a carefully selected laser into the examined substance. Light travels through the measured air in a multireflection cuvette, achieving several tens of meters of measurement distance and a sufficient sensitivity even with concentrations this small. The computer-controlled device sucks the gas to be measured using its own sampling pump.

An equivalent analyser that is modular and measures several gases simultaneously with such low concentrations has not thus far been in professional use in Finland.

The developed prototype is now technically ready for use, and we are seeking for a productiser and new applications for it.

Photo: Research Scientist Jussi Hämäläinen is measuring ammonia and formaldehyde concentrations in ambient air with a laser-based online analyser.

Liat

Recent Posts

Renesas Unveils Industry’s First 650V GaN in Dual-Side Cooled 8x8mm Package for Megawatt-Scale AI Data Centers

Dual-side cooling (DSC) shrinks package footprint by 57% compared with TOLT, packing more power into…

20 hours ago

Leica Microsystems launches AI software module for consistent inspection decisions

Supporting manufacturers with reliable defect identification and scalable quality control across production lines Leica Microsystems,…

20 hours ago

Teradyne Introduces Near-DUT Test Platform for LPDDR6, DDR6 and GDDR7

The Magnum E2 system supports emerging DRAM and NAND interfaces while using common hardware and…

20 hours ago

ARX Robotics and DEUTZ Deliver First Ulm-Built GEREON UGVs to Ukraine

The first unmanned ground systems left the production line only 12 weeks after the two…

20 hours ago

AMD Releases Ross Agentic Assistant for Vivado and Vitis HLS Workflows

The available-now engineering assistant connects language models to AMD development tools, documentation and reusable FPGA…

20 hours ago

Murata Begins Mass Production of 0201-Inch Three-Terminal Low-ESL MLCCs

The 0.6 × 0.3 mm capacitors occupy 64% less mounting area than Murata’s previous smallest…

21 hours ago